We provide every aspect from concept drawing, schematic drawing, design drawing stage, tender stage. We not only take-up MEP design and drafting services, we also help in MEP design services as per local building code and do heat load | cooling load calculations according to building zone with ASHRAE Standards.

All kind of detail Drawing MEP Services like

MEP BIM coordination services

Design & Drafting Services in Mechanical, Electrical, Plumbing & Fire Fighting

Design & BIM Services

Produce permit set drawings

The design process includes

Reading and understanding the contract and Arch set: It is crucial to read and comprehend the contract and architectural drawings in order to understand the project's scope of work and plan how to proceed with the design.

Developing mechanical permit drawing set: Proficient in developing mechanical permit drawing sets, including following design stages such as Schematic Design, Design Development, and Construction Documents, and submitting completed drawing sets for review and permit approval by the relevant authorities.

Construction Administration: This involves addressing plan reviewer comments, issuing bulletin drawings, responding to requests for information (RFIs), accommodating architectural changes, and reviewing contractor submittals.

MECHANICAL

Schematic Design (SD)

Code study: IMC, IECC, IBC, EBC, ASHRAE 90.1, ASHRAE 62.1 & 62.2

Preliminary ventilation study and load study using Ashrae handbook table 12.1 and IMC table 403.3.1.1 at the schematic design level.

Suggest possible HVAC equipment type and possible location of the units.

Note down the point to discuss and critical design questions and data needed to proceed to the next stage of design.

Schedule a meeting and discuss the design with the client and conclude on the critical design questions and other dependencies

Design Development (DD)

Do complete thermal load calculations using the right suite of software

Select appropriate HVAC equipment. And place the equipment over the approved location.

Draft the duct layout and schedule all the equipment and add general and plan not and set the sheets using Revit software.

Add details, general notes, and specifications to the sheet.

Submit the developed design set to the client for review.

Construction Document (CD)

Produce the final drawing set.

Add energy compliance certificate using COMcheck if required.

Stamp the drawings and submit them to AHJ (Authority Having Jurisdiction) for review.

Construction Administration

Any architectural drawing changes and review comments from the AHJ will be addressed, and necessary changes in the design will be made, and submit the drawing to AHJ as Bulletin drawings.

Submittal review: after the permit is issued and before starting the construction, the contractor is supposed to submit the spec sheets of the equipments, grilles, etc., they are going to buy or use for the project to the EOR (Engineer Of Record) for review. If the submitted equipment satisfies and aline with what is specified on the latest submitted contract drawing, the submittal will be approved, or it will be approved with some notes or will be asked to revise and resubmit the submittal.

RFI: during the construction phase, there may be some additional information or clarification required by the contractor from the design consultant to complete the construction of the mechanical systems. We will be scheduling a meeting or addressing the RIF through an RFI letter with proper clarification and direction to the contractor.

ELECTRICAl

Schematic Design (SD)

Code study: Includes the identification of applicable local (City or county code of ordinances), and International codes (National Electrical Code, International Building Codes & Energy Codes). Studying applicability of above mentioned codes related to the Project.

Preliminary Service Load Calculation: Includes preliminary service calculation based on NEC standards with available electrical load details. The intention of this design phase is to have a rough idea on the service requirement, and service equipment infrastructure preliminary plannings.

Primary Planning for Electrical Layouts : This includes laying electrical plans and proposing code required outlets (we provide code minimum outlets, and outlets equipment specified locations. Further outlet requirement to be marked on SD meeting), and light fixture controls (fixture control locations to be finalized in an SD meeting) etc.

SD Meeting: Arrange a meeting with the client and discuss the design questions, and markdown dependencies to complete the design.

Design Development (DD)

This phase includes the development of the design to a 70-90% set.

Submit the developed design set to the client for review.

Follow up on the dependencies per SD meeting.

Construction Document (CD)

All the dependencies shall be cleared before promising a construction document set.

CD Set is the 100% developed design set which includes ready to stamp electrical drawing with standard details, Lighting compliance certificates, and city checklists (if required).

Construction Administration

Addressing architectural changes, AHJ Review comments after submission, and resubmitting revised drawings to clients as Bulletin sets.

Submittal review: Technical review of the submittals from contractors including Equipment, and light fixtures etc prior to beginning of construction.

RFI: Additional information requests will be addressed through professional letters during construction.

Plumbing

Domestic Cold & Hot Water Supply & Return.

In Drainage Services we provide Soil Pipe Solution, Waste Water Solution, Vent Layout Etc.

Schematic Design (SD)

Code study: IPC, IFGC, IECC, IBC, EBC, ICC/ANSI A117.1-2009 ADA STANDARDS

Find and research on applicable local codes and standards for designing the plumbing system. This is to make sure that we don’t violate any of the local codes, laws or standards while designing the system.

Preliminary load calculation for sizing of water supply using the WSFU values. This includes sizing of water meter and sizing of main distribution piping.

Preliminary load calculation for sizing of sanitary/vent system using the DFU values. This includes the sizing of main building lateral and vent through roof sizing.

Preliminary load calculation for sizing gas service using the pressure available, approximate length of the piping, total equipment load (CFH or BTU/HR).

Preliminary sizing of water heaters, booster pump, sump pumps if applicable.

Note down the point to discuss and critical design questions and data needed to proceed to the next stage of design.

Schedule a meeting and discuss the design with the client and conclude on the critical design questions and other dependencies to move forward to DD

Design Development (DD)

Do complete thermal load calculations using the right suite of software

Select appropriate HVAC equipment. And place the equipment over the approved location.

Draft the duct layout and schedule all the equipment and add general and plan not and set the sheets using Revit software.

Add details, general notes, and specifications to the sheet.

Submit the developed design set to the client for review.

Construction Document (CD)

Produce the final drawing set.

Add energy compliance certificate using COMcheck if required.

Stamp the drawings and submit them to AHJ (Authority Having Jurisdiction) for review.

Construction Administration

Any architectural drawing changes and review comments from the AHJ will be addressed, and necessary changes in the design will be made, and submit the drawing to AHJ as Bulletin drawings.

Submittal review: after the permit is issued and before starting the construction, the contractor is supposed to submit the spec sheets of the equipments, grilles, etc., they are going to buy or use for the project to the EOR (Engineer Of Record) for review. If the submitted equipment satisfies and aline with what is specified on the latest submitted contract drawing, the submittal will be approved, or it will be approved with some notes or will be asked to revise and resubmit the submittal.

RFI: during the construction phase, there may be some additional information or clarification required by the contractor from the design consultant to complete the construction of the mechanical systems. We will be scheduling a meeting or addressing the RIF through an RFI letter with proper clarification and direction to the contractor.

Fire Fighting Services we provide

Sprinkler System

Pump Layout

Pump Head Calculation

Water Capacity

Showing Breach Inlet etc.

Pre-fabrication

Field drawing preparation

Material take-off

Hydraulic calculation

We the whole team will coordinate with each service like Mechanical, Electrical, Architectural Drawings and Structural Drawings. We are also preparing Schematic Diagram, Shop drawings, Coordinated drawing, As built drawings etc.

PROJECTS

More on MEP Design

We specialized in providing excellent consulting service in mechanical, electrical and plumbing.

Learn More

HVAC CAD outsourcing services division provides detailed HVAC duct sizing with its correct velocity and friction loss basis to get perfect NC. We also mention diffusers, dampers, grills selection and sizes. With our well experienced HVAC cad drafting team with international CAD standards, your project will always be in right hands.

Learn More

Behind every skyscraper, there will be an efficient design which supported them all the way ahead. With excellent design, it is assured that your project is always on right track. Our main objective is to achieve that perfect design so that nothing can come between you and your dream project.

Learn More

Drafting a complete plan for your electrical requirement need time and dedication, it can only be achieved by a highly skilled team with adequate experience.

Learn More

“Plumbing” often signifies the supply and waste system of an individual building. The system consists of drainage, piping, its fittings, valves and fixtures which shall be installed for the supply of potable drinking water and daily usages in any building.

Learn More

Fire protection is an important element when it comes to a building or construction. In order to ensure a complete fire protection Design and Drafting Services, we prepare the drawings as per the civil defense department’s approval either in NFPA standards or individual international standards.

Learn More

Other Services

We are one of the leading outsourcing company concentrating in AEC services sector. Cadeosys executed several projects in architectural, structural, and MEP | electromechanical.

Learn More

We are proud of our drafting employees who are well experienced with international drafting standards, with their support and contribution we can design impeccable drafting services by meeting the exact preference of clients.

Learn More

We are one of the leading CAD | BIM engineering processing outsourcing (EPO) and MEP consultancy and sub consultancy.

Learn More

We offer all kind of Mechanical drawings such as Automobile, Aerospace etc..

Learn More

We offer Structural drawings in 2D & 3D. Whether it is a private residence, resort, office or retail environment, Cadeosys always strive to deliver elegant design and drafting experience to the end user.

Learn More

We provide BIM services to our clients in order to help them transition easily from traditional 2D CAD and paper-based drawings and designs to virtual construction documentations in the form of 3D BIM models.

Learn More